IAQ MONITOR MODEL 2212

IAQ MONITOR MODEL 2212

Simultaneously measures multiple parameters such as: CO, CO2, Temperature, RH, to monitor IAQ

CHARACTERISTIC


Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air.
The 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments.
Easy user self-calibration.
The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62.
Examines building IAQ conditions to optimize worker productivity.
NIST Traceable Calibration Certificate.
Features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment.
Sampling function records multiple point measurements.
The 2212 is an outstanding instrument for IAQ (Indoor Air Quality) investigation and spot checks to ensure an indoor environment remains within desired levels to maintain occupant health and comfort.

  • Allows user to store up to 1500 multiple measurements.
  • Easy replacement of probe.
  • Data Processing Software (DPS), which permits easy transfer of data to your company computer, is included.
  • Software statistics function displays average, maximum and minimum values, and the number of recorded samples.
  • Verifies building HVAC system performance to comply with regulations and guidelines.

USE


  • IAQ Investigation
  • Building Commissioning
  • Thermal Comfort Control
  • Employee Health
  • Industrial Hygiene

SPECIFICATIONS


Measurement Specifications
CO Range 0 to 500PPM
Accuracy +/-3% of reading or +/-3PPM
whichever is greater
Resolution 0.1PPM: 0-99PPM 1PPM: 100-500 PPM
CO2 Range 0 to 5000PPM
Accuracy +/-3% of reading or+/-50PPM
whichever is greater
Resolution 1PPM
Temperature Range – 4 to 140F (-20 to 60C)
Accuracy +/- 1F (+/-0.5C)
Resolution 0.1F (0.1C )
Relative Humidity Range 2 to 98%RH
Accuracy 2 to 80%RH:±2%RH,
80 to 98%RH:±3%RH
Resolution 0.1%RH
General Specifications
Function Normal Mode Normal measuring (do not store and calculate the data.)
Relative humidity, CO, CO2, Dew point,
Wet bulb temperature,
Absolute humidity and Humidity Ratio
Calculation Mode Store the data, and calculate the maximum,
minimum and average value.
% OA Mode Measure ventilation ratio
(Ask for ventilation ratio by calculating
from temperature and CO2 value)
Data Output Mode Perform re-calculation of stored data
and output of data to PC and Printer.
Calibration Mode Perform the calibration of CO and CO2.
Output Digital RS232C
Analog (option) DC 0 to 1V
Power Supply   AAA Battery x 4 (Mn, Alkaline, or Ni-Cd)
Analog (option) DC 0 to 1V
Dimensions Unit 3.5″ x 7.5″ x 2.0″
Probe Length: 12.5 inch / Diameter: 1.0 inch
Weight   1.2 lbs (500g))
What’s included   Meter, Operation manual, AA batteries,
Probe stand,Probe, Calibration cap,
Connection tube, Data processing software(DPS),
RS-232C cable, USB to serial adapter,
Carrying case, NIST TRACEABLE CALIBRATION certificate

ACCESSORIES


  • Probe
  • Hand Carrying Case
  • Calibration Cap & Connection Tube
  • Probe Stand
  • Data Processing Software
  • RS232C Cable
  • 6 x AA batteries
  • User Manual
  • Calibration Certificate

OPTIONAL ITEMS


  • Spare Probe
  • Spare Carrying Case
  • Spare Probe Stand
  • Spare Gas Calibration Cap
  • Flow Control Valve
  • Analog Output
  • Spare Connection Tube
  • Spare Communication PC
  • Printer Cable for DPU-S245
  • AC Adapter
  • Portable Thermal Printer
  • Rolled Printer Paper(10 rolls)

FAQ

What does the IAQ Monitor Model 2212 measure?

This instrument can simultaneously measure CO, CO2, temperature and relative humidity. It also has the ability to calculate dew point, wet bulb temperature, absolute humidity, humidity ratio and percentage of outside air.

How often does the unit need to be calibrated?

Annual calibration is recommended to ensure accuracy. However, this can vary based on how often the IAQ monitor is used and the environments it’s used it. Also, some companies have an SOP in place that specifies how often the instrument will need to be serviced. More specifically, regulatory compliances may dictate the calibration interval.

What operating system is the software compatible with?

Windows XP (32-bit only), Vista, & Windows 7.

CONTACT