General Specifications | |
Measurements Units | Gas: ppm or mg/m3, Temperature: ℃ or ℉, Humidity: % |
---|---|
Temperature & Humidity Sensor | Temperature: -40 to 124℃, Humidity: 0 to 100%RH |
Environmental Operating Conditions | Temperature: -5 to 45℃, Humidity: 0 to 95% (*without condensation) |
Analog Output | 0 to 5V |
Digital Interface | RS-232 to USB |
Data Storage | Max. 8,188 data |
Data Logging | PC software (*Windows) |
Power Supply | AC100 to 250V |
Size | Approx. 195 x 122 x 54 (mm) (*including sensor head) |
Weight | Approx. 460g (*including sensor head & Battery) |
Warranty | For 1 year after the purchase date |
Sensor | Range (ppm) |
Accuracy of Calibration |
Min. Detection Limit(ppm) |
Resolution (ppm) |
Operational Temperature Range |
Operational RH Range |
---|---|---|---|---|---|---|
Ammonia (NH3) | 0-100 | <±5 ppm +15% | 0.2 | 0.1 | 0-40℃ | 15-90% |
Ammonia (NH3) | 0-1000 | <±5 ppm +15% | 2 | 1 | 0-40℃ | 10-90% |
Carbon Monoxide (CO) | 0-25 | <±0.5 ppm (0-5 ppm) | 0.05 | 0.01 | 0-40℃ | 15-90% |
<±10% (5-25 ppm) | ||||||
Carbon Monoxide (CO) | 0-100 | <±1 ppm (0-10 ppm) | 0.2 | 0.1 | 0-40℃ | 15-90% |
<±10% (10-100 ppm) | ||||||
Carbon Monoxide (CO) | 0-1000 | <±2 ppm +15% | 1 | 1 | 0-40℃ | 10-90% |
Carbon Dioxide (CO2) | 0-2000 | <±10 ppm +5% | 10 | 1 | 0-40℃ | 0-95% |
Carbon Dioxide (CO2) | 0-5000 | <±20 ppm +5% | 20 | 1 | 0-40℃ | 0-95% |
Chlorine (Cl2) | 0-10 | <±0.02 ppm +10% | 0.01 | 0.01 | 0-40℃ | 15-90% |
Formaldehyde (CH2O) | 0-10 | <±0.05 ppm (0-0.5 ppm) | 0.01 | 0.01 | 0-40℃ | 15-90% |
<±10% (0.5-10 ppm) | ||||||
Hydrogen (H2) | 0-5000 | <±10 ppm +10% | 5 | 1 | 0-40℃ | 10-90% |
Methane (CH4) | 0-10000 | <±20 ppm +15% | 10 | 1 | 0-40℃ | 10-90% |
Hydrogen Sulphide (H2S) | 0-10 | <±0.05 ppm (0-0.5 ppm) | 0.04 | 0.01 | 0-40℃ | 15-90% |
<±10% (0.5-10 ppm) | ||||||
Hydrogen Sulphide (H2S) | 0-100 | <±0.5 ppm (0-5 ppm) | 0.4 | 0.1 | 0-40℃ | 15-90% |
<±10% (5-100 ppm) | ||||||
Nitrogen Dioxide (NO2) | 0-1 | <±0.02 ppm (0-0.2 ppm) | 0.005 | 0.001 | 0-40℃ | 15-90% |
<±10% (0.2-1 ppm) | ||||||
NMHC | 0-25 | <±0.1 ppm +10% | 0.1 | 0.1 | 0-40℃ | 10-90% |
Ozone (O3) | 0-0.05 | <±0.002 ppm | 0.001 | 0.001 | 0-40℃ | 10-90% |
Ozone (O3) | 0-0.15 | <±0.005 ppm | 0.001 | 0.001 | 0-40℃ | 10-90% |
Ozone (O3) | 0-0.5 | <±0.008 ppm (0-0.01 ppm) | 0.001 | 0.001 | 0-40℃ | 10-90% |
<±10% (0.1-0.5 ppm) | ||||||
Ozone (O3) | 0-10 | <±0.01 ppm +7.5% | 0.01 | 0.01 | 0-40℃ | 15-90% |
Ozone (O3) | 0-30 | <±0.05 ppm +10% | 0.01 | 0.01 | 0-40℃ | 15-90% |
Particulate Matter (PM2.5 and PM10) |
0.001-1.000 mg/m3 | ±0.005 mg/m3 +15% | 0.001 mg/m3 | 0.001 mg/m3 | 0-40℃ | 0-90% |
Perchloroethylene (C2Cl4) | 0-200 | <±5 ppm (0-50 ppm) | 1 | 1 | 0-40℃ | 10-90% |
<±10% (50-200 ppm) | ||||||
Sulphur Dioxide (SO2) | 0-10 | <±0.05 ppm (0-0.5 ppm) | 0.04 | 0.01 | 0-40℃ | 15-90% |
<±10% (0.5-10 ppm) | ||||||
Sulphur Dioxide (SO2) | 0-100 | <±0.5 ppm (0-5 ppm) | 0.4 | 0.1 | 0-40℃ | 15-90% |
<±10% (5-100 ppm) | ||||||
VOC (*GSS) | 0-25 | <±0.1 ppm +10% | 0.1 | 0.1 | 0-40℃ | 10-90% |
VOC (*GSS) | 0-500 | <±5 ppm +10% | 1 | 1 | 0-40℃ | 10-90% |
VOC (*PID) | 0-30 | <±0.02 ppm +10% | 0.01 | 0.01 | 0-40℃ | 0-95% |
VOC (*PID) | 0-2000 | <±0.2 ppm +10% | 0.1 | <1000 ppm: 0.1 | 0-40℃ | 0-95% |
>1000 ppm: 1 |
Choose our Handheld Gas Monitor are designed for easy and affordable measurement of indoor and industrial air quality. Indoor air quality consultants
They are used by health and safety experts at industrial and commercial sites as well as researchers who are interested in measuring hot spots and testing personal exposure to harmful indoor gases.